10 Ton Gas Steam Boiler Manufacturer

 The gas-fired steam boiler adopts the automatic program control of the microcomputer intelligent burner, with a high degree of automation, which can make the boiler achieve a good combustion effect. The heating surface of the boiler is designed for computer simulation control, and the heating surface and the flow of flue gas have been optimized. The structure is more compact and the installation and maintenance are more convenient. Adopt high-grade centrifugal glass wool multi-layer insulation, less heat loss; imported color steel plate packaging, beautiful appearance. It can provide heating and domestic hot water for hotels, schools, baths and other enterprises and institutions.



This series of boiler gas is equipped with low pressure and leakage alarm. The advanced microcomputer intelligent control technology can remotely monitor and diagnose faults. Centralized control of multiple boilers can also be designed. WNS series boiler flue pipes have built-in spoilers to enhance heat transfer, thereby reducing convective heating area and reducing boiler costs.

The boiler adopts thermal insulation material, which has good thermal insulation performance, light weight and low cost. The boiler is equipped with safety valve and other overpressure safety protection devices, which can make the boiler run more. This series of boiler products have reasonable structure and performance after various furnace design, demonstration and technical index comparison.

The combustion system of the 10-ton gas steam boiler adopts the original brand burner, equipped with flameout protection, water shortage protection, temperature protection, and safety protection. With time control function, the switch time can be set arbitrarily according to user needs, and faults can be automatically recorded, which is convenient for maintenance.



The WNS series steam boiler control system adopts intelligent computer controller, which has automatic control functions such as automatic, combustion, and circulation control, and is easy to operate. The water temperature control has automatic control functions such as digital temperature display, temperature control, over-temperature protection, etc. The user can set the water temperature arbitrarily between 30°C and 90°C to ensure energy saving and high efficiency.

E-mail us: sunhui@zozen.com


Comments

Popular posts from this blog

Parameters and technical requirements of 6-ton gas-fired steam boiler for hospital use

 The 6ton gas-fired steam boiler is commonly used in hospitals, and its process requirements are as follows: Natural gas boiler: natural gas → burner → boiler → steam → sub-cylinder → steam point. Tap water constant pressure water supply → water softener → soft water insulation water tank → energy saver → boiler. Hospitals are densely populated places, so the requirements for boiler equipment and suppliers are relatively strict. Suppliers of 6ton gas boilers must have a Class A boiler manufacturing license, a pressure vessel manufacturing license, a Class 2 boiler installation, renovation and maintenance license or above. The equipment supplier shall be responsible for obtaining relevant certificates and fees such as the registration certificate for installation and use of boiler equipment. The water supply of this series of gas boilers is designed with a flue gas condensation recovery device to recover the heat energy of the flue gas, and the exhaust gas temperature is less than...

SZS Gas-Fired Horizontal Water-Tube Saturated Steam Boiler

 The pipelines within the scope of the SZS watertube steam boiler only include the valves and pipelines from the flange of the return water check valve to the outlet valve and drain valve of the boiler body. Accessories include valves and gauges for the boiler body. Such as pressure gauges, air valves, spring safety valves, outlet and return valves, check valves, thermometers, etc. The SZS gas-fired steam boiler is equipped with a flue gas condenser at the tail of the boiler body, which reduces the flue gas temperature (<70°C), improves the boiler efficiency and reduces the harmful components in the flue gas. The boiler adopts micro-positive pressure combustion, and the furnace wall tube is a full-membrane wall structure. This series of boiler products has a certain pressure bearing capacity, and no smoke leakage and air leakage will occur when running under a slightly positive pressure state. The boiler is a self-contained boiler, which can shorten the installation period whi...

35 Tons SZS Gas Steam Boiler

 The SZS gas fired steam boiler is equipped with a flue gas condenser at the tail of the boiler body, which reduces the temperature of the flue gas, improves the efficiency of the boiler, and reduces the harmful components in the flue gas. The szs gas boiler adopts micro-positive pressure combustion, and the furnace wall tube is a full-membrane wall structure. The 35ton gas-fired boiler has a certain pressure-bearing capacity, and there will be no smoke leakage and air leakage when running under a slightly positive pressure state. The boiler is a self-contained boiler, which can shorten the installation period while meeting the transportation size requirements. At the same time, the aluminum casing and the skeleton are transported and connected by bolts, which are convenient for disassembly and maintenance. The furnace of this series of boiler products adopts a model water-cooled wall structure, and the whole boiler adopts an air-tight inner shield with a fully enclosed welding s...