Skip to main content

35 Tons SZS Gas Steam Boiler

 The SZS gas fired steam boiler is equipped with a flue gas condenser at the tail of the boiler body, which reduces the temperature of the flue gas, improves the efficiency of the boiler, and reduces the harmful components in the flue gas. The szs gas boiler adopts micro-positive pressure combustion, and the furnace wall tube is a full-membrane wall structure.



The 35ton gas-fired boiler has a certain pressure-bearing capacity, and there will be no smoke leakage and air leakage when running under a slightly positive pressure state. The boiler is a self-contained boiler, which can shorten the installation period while meeting the transportation size requirements. At the same time, the aluminum casing and the skeleton are transported and connected by bolts, which are convenient for disassembly and maintenance.

The furnace of this series of boiler products adopts a model water-cooled wall structure, and the whole boiler adopts an air-tight inner shield with a fully enclosed welding structure, and the furnace wall has good sealing performance. The heating surface area of ​​the boiler layout is large, and the design has a large enough space for steam and water to ensure the stability of the boiler parameters. The high thermal resistance material is used as the thermal insulation layer, and the thermal insulation performance is good. The outer layer of the boiler adopts a pressed guard plate, which has a beautiful and beautiful appearance.

SZS series steam boiler adopts quick-installation structure, and the whole boiler is designed on a strong steel base, which is convenient for installation and transportation. The furnace is equipped with inspection holes, which provides great convenience for use and maintenance. There is an explosion-proof door on the top of the furnace. The automatic burner is adopted, and the water supply adopts continuous electric adjustment, and the combustion efficiency is high. And has multiple protection functions, safe and reliable operation.



The radiant heating surface of the gas-fired steam boiler is a fully corrugated furnace, the convection heating surface adopts a threaded smoke pipe, and a flue gas condensation recovery device is arranged at the tail. The SZS boiler adopts a quick-installation structure, which is convenient for installation and transportation, and occupies a small area.

WhatsApp: +8618861589023


Comments

Popular posts from this blog

Parameters and technical requirements of 6-ton gas-fired steam boiler for hospital use

 The 6ton gas-fired steam boiler is commonly used in hospitals, and its process requirements are as follows: Natural gas boiler: natural gas → burner → boiler → steam → sub-cylinder → steam point. Tap water constant pressure water supply → water softener → soft water insulation water tank → energy saver → boiler. Hospitals are densely populated places, so the requirements for boiler equipment and suppliers are relatively strict. Suppliers of 6ton gas boilers must have a Class A boiler manufacturing license, a pressure vessel manufacturing license, a Class 2 boiler installation, renovation and maintenance license or above. The equipment supplier shall be responsible for obtaining relevant certificates and fees such as the registration certificate for installation and use of boiler equipment. The water supply of this series of gas boilers is designed with a flue gas condensation recovery device to recover the heat energy of the flue gas, and the exhaust gas temperature is less than...

SZS Gas-Fired Horizontal Water-Tube Saturated Steam Boiler

 The pipelines within the scope of the SZS watertube steam boiler only include the valves and pipelines from the flange of the return water check valve to the outlet valve and drain valve of the boiler body. Accessories include valves and gauges for the boiler body. Such as pressure gauges, air valves, spring safety valves, outlet and return valves, check valves, thermometers, etc. The SZS gas-fired steam boiler is equipped with a flue gas condenser at the tail of the boiler body, which reduces the flue gas temperature (<70°C), improves the boiler efficiency and reduces the harmful components in the flue gas. The boiler adopts micro-positive pressure combustion, and the furnace wall tube is a full-membrane wall structure. This series of boiler products has a certain pressure bearing capacity, and no smoke leakage and air leakage will occur when running under a slightly positive pressure state. The boiler is a self-contained boiler, which can shorten the installation period whi...