 The operators of gas-fired steam boilers shall be trained and certified to work, and have a deep familiarity with boiler performance and operation related knowledge. Irrelevant personnel are not allowed to enter or leave the boiler room. The ignition precautions for gas-fired steam boilers are as follows.

Before ignition of this series of boilers product, a hydraulic test must be done, and the flue and furnace must be ventilated. Before operating the gas boiler, check whether the boiler and its accessories are in good condition and meet the requirements, such as the normal conditions of water pumps, oil pumps, filters and natural gas pressure. Strictly abide by the boiler safety operation system, do a good job in inspections, and frequently check the operating status of the equipment , Make a good record of boiler operation, and report any abnormal conditions to be resolved in time, and the boiler can be operated only after the fault is resolved. Manage the fire-fighting facilities in the boiler room well, and do not conduct hot work at will. Keep the boiler clean. Do a good job in the maintenance of gas steam boiler equipment to ensure its safe and normal operation. Ensure that the quality of boiler feed water meets national requirements.



Features of Gas Fired Steam Boiler

1. Our company mainly produces water tube boilers with membrane wall structure, and is also equipped with high temperature superheaters according to requirements.

2. The gas-fired steam boiler adopts low-resistance heat transfer technology and high-expansion heating surface. The exhaust gas temperature and large-capacity industrial boiler are basically *, 150-180℃.

3. Fully intelligent automatic control and equipped with multi-level protection system, not only equipped with complete automatic combustion control device, but also multi-level safety protection, the system protects the boiler against water shortage, overpressure, overtemperature, flameout, and ignition Program control and sound, light and electric alarm system.

4. Compared with coal-fired steam boilers, the ash content, sulfur content and nitrogen content in the flue gas composition after combustion of gas fired boilers are greatly reduced, and the degree of environmental pollution is also greatly reduced.

5. The heat load of the gas boiler furnace is high, so the furnace volume becomes smaller. There is no bad problems such as heating surface pollution, slagging, abrasion, etc., and there is no dust collector and feeding and slagging system, so the operating cost is very low.



The WNS series steam boiler is a shell-type full wet-back downstream three-pass pyrotechnic tube structure. The flame burns in a large combustion chamber with slight positive pressure, fully extended, low combustion heat load, high combustion heat efficiency, and effectively reduces the exhaust gas temperature and saves energy. Reduce consumption, use more economical, adopt the structure of corrugated furnace bladder and threaded smoke tube, which not only improves the heat absorption strength of the boiler, but also meets the needs of thermal expansion of the heat exchange surface, which is scientific and reasonable and durable.

E-mail us: sunhui@zozen.com


Comments

Popular posts from this blog

Parameters and technical requirements of 6-ton gas-fired steam boiler for hospital use

 The 6ton gas-fired steam boiler is commonly used in hospitals, and its process requirements are as follows: Natural gas boiler: natural gas → burner → boiler → steam → sub-cylinder → steam point. Tap water constant pressure water supply → water softener → soft water insulation water tank → energy saver → boiler. Hospitals are densely populated places, so the requirements for boiler equipment and suppliers are relatively strict. Suppliers of 6ton gas boilers must have a Class A boiler manufacturing license, a pressure vessel manufacturing license, a Class 2 boiler installation, renovation and maintenance license or above. The equipment supplier shall be responsible for obtaining relevant certificates and fees such as the registration certificate for installation and use of boiler equipment. The water supply of this series of gas boilers is designed with a flue gas condensation recovery device to recover the heat energy of the flue gas, and the exhaust gas temperature is less than...

SZS Gas-Fired Horizontal Water-Tube Saturated Steam Boiler

 The pipelines within the scope of the SZS watertube steam boiler only include the valves and pipelines from the flange of the return water check valve to the outlet valve and drain valve of the boiler body. Accessories include valves and gauges for the boiler body. Such as pressure gauges, air valves, spring safety valves, outlet and return valves, check valves, thermometers, etc. The SZS gas-fired steam boiler is equipped with a flue gas condenser at the tail of the boiler body, which reduces the flue gas temperature (<70°C), improves the boiler efficiency and reduces the harmful components in the flue gas. The boiler adopts micro-positive pressure combustion, and the furnace wall tube is a full-membrane wall structure. This series of boiler products has a certain pressure bearing capacity, and no smoke leakage and air leakage will occur when running under a slightly positive pressure state. The boiler is a self-contained boiler, which can shorten the installation period whi...

35 Tons SZS Gas Steam Boiler

 The SZS gas fired steam boiler is equipped with a flue gas condenser at the tail of the boiler body, which reduces the temperature of the flue gas, improves the efficiency of the boiler, and reduces the harmful components in the flue gas. The szs gas boiler adopts micro-positive pressure combustion, and the furnace wall tube is a full-membrane wall structure. The 35ton gas-fired boiler has a certain pressure-bearing capacity, and there will be no smoke leakage and air leakage when running under a slightly positive pressure state. The boiler is a self-contained boiler, which can shorten the installation period while meeting the transportation size requirements. At the same time, the aluminum casing and the skeleton are transported and connected by bolts, which are convenient for disassembly and maintenance. The furnace of this series of boiler products adopts a model water-cooled wall structure, and the whole boiler adopts an air-tight inner shield with a fully enclosed welding s...