Skip to main content

Condensing Horizontal Gas Steam Boiler

 The horizontal gas-fired steam boiler adopts the corrugated furnace bladder and the re-combustion chamber for one return, the second and third returns are threaded smoke tubes, and an energy saver is arranged on the boiler. The boiler is equipped with complete automatic control devices and safety protection devices with high and low water level alarms and low water level interlocking protection functions; automatic ignition of the boiler, automatic adjustment of the burner power and flameout protection to ensure the safe operation of the boiler.



The fuel of this boilers product is light oil or natural gas; the fuel is ejected from the burner, ignited by the electronic ignition rod, and burned in the furnace with slight positive pressure. The high-temperature flue gas after burning is turned 180° into the second, The three-pass threaded smoke pipe turns 180° from the upper part of the rear smoke box into the economizer for heat exchange and is discharged into the atmosphere through the chimney.

The design and production of gas-fired steam boilers fully consider the safety needs of actual working conditions, and have various complete safety protection functions; equipped with high-performance electrical instruments and components, as well as a humanized digital control system, various operating instructions, and fault display , Operation status display, etc., the cause of the fault is clear at a glance, the fault signal can be connected to the electric control box or directly outside the boiler room to ensure the safe operation of the boiler under the monitoring.



The condensing gas boiler has a small unit heat volume load, a long service life of the boiler, and low NOX emission. The caliber, length and arrangement of the drum and smoke tube have been precisely calculated, and then combined with advanced manufacturing technology to produce a high-quality steam boiler. The furnace bladder and the front and rear tube plates are all crimped butt welded. Both the shell and the front and rear tube plates are crimped butt welded. The back smoke chamber of the furnace also adopts the crimping butt welding structure. The second/third return smoke pipe is equipped with a bypass strip to break the heat exchange of the boundary layer of the enhanced smoke pipe and improve the thermal efficiency. All the flue pipes of the boiler and the front and rear tube plates are first expanded and then TIG welded.

E-mail us: sunhui@zozen.com


Comments

Popular posts from this blog

Parameters and technical requirements of 6-ton gas-fired steam boiler for hospital use

 The 6ton gas-fired steam boiler is commonly used in hospitals, and its process requirements are as follows: Natural gas boiler: natural gas → burner → boiler → steam → sub-cylinder → steam point. Tap water constant pressure water supply → water softener → soft water insulation water tank → energy saver → boiler. Hospitals are densely populated places, so the requirements for boiler equipment and suppliers are relatively strict. Suppliers of 6ton gas boilers must have a Class A boiler manufacturing license, a pressure vessel manufacturing license, a Class 2 boiler installation, renovation and maintenance license or above. The equipment supplier shall be responsible for obtaining relevant certificates and fees such as the registration certificate for installation and use of boiler equipment. The water supply of this series of gas boilers is designed with a flue gas condensation recovery device to recover the heat energy of the flue gas, and the exhaust gas temperature is less than...

SZS Gas-Fired Horizontal Water-Tube Saturated Steam Boiler

 The pipelines within the scope of the SZS watertube steam boiler only include the valves and pipelines from the flange of the return water check valve to the outlet valve and drain valve of the boiler body. Accessories include valves and gauges for the boiler body. Such as pressure gauges, air valves, spring safety valves, outlet and return valves, check valves, thermometers, etc. The SZS gas-fired steam boiler is equipped with a flue gas condenser at the tail of the boiler body, which reduces the flue gas temperature (<70°C), improves the boiler efficiency and reduces the harmful components in the flue gas. The boiler adopts micro-positive pressure combustion, and the furnace wall tube is a full-membrane wall structure. This series of boiler products has a certain pressure bearing capacity, and no smoke leakage and air leakage will occur when running under a slightly positive pressure state. The boiler is a self-contained boiler, which can shorten the installation period whi...

35 Tons SZS Gas Steam Boiler

 The SZS gas fired steam boiler is equipped with a flue gas condenser at the tail of the boiler body, which reduces the temperature of the flue gas, improves the efficiency of the boiler, and reduces the harmful components in the flue gas. The szs gas boiler adopts micro-positive pressure combustion, and the furnace wall tube is a full-membrane wall structure. The 35ton gas-fired boiler has a certain pressure-bearing capacity, and there will be no smoke leakage and air leakage when running under a slightly positive pressure state. The boiler is a self-contained boiler, which can shorten the installation period while meeting the transportation size requirements. At the same time, the aluminum casing and the skeleton are transported and connected by bolts, which are convenient for disassembly and maintenance. The furnace of this series of boiler products adopts a model water-cooled wall structure, and the whole boiler adopts an air-tight inner shield with a fully enclosed welding s...